The CAS BCD Series is a highly accurate single point load cell. It is ideal for OEM applications such as electronic scales and weighing machines. The single point design is highly resistant to eccentric loading allowing direct mounting to the scale base and weighing platform.
Specifications
Max Capacity (rated load) |
kgf |
100, 150, 250, 300 |
Rated Output
Zero Balance |
mv/v
mv/v |
2.0 ± 0.2
0.0 ± 0.1 |
Accuracy Class |
- |
- |
Non-Linearity
Hysteresis
Combined Error
Repeatability
Creep for 30min
Return for 30min
Resolution
Division |
%RO
%RO
%RO
%RO
%RO
%RO
-
mV/V |
0.03
0.03
0.03
0.01
0.03
0.03
≤1/3000
0.00067 |
Temperature Effect On
Zero Value
Output Value |
%/10°C
%/10°C |
0.028
0.014 |
Excitation
Recommended
Maximum |
V
V |
-
10
15 |
Resistance
Input
Output
Insulation |
-
Ω
Ω
MΩ |
-
420 ± 20
350 ± 3.5
>2000 |
Compensated Temperature Range
Operating Temperature Range |
°C
°C |
-10 to +40
-20 to +70 |
Material & Plate |
- |
Anodised Aluminium |
Cable Specification |
- |
ø5 x 4p x 1.5M (P.V.C) |
Safety Overload |
%RL |
150%RL |
Platform Size |
mm |
400 x 600 |